Cleanroom STANDARDS & CLEANLINESS

To clean rooms, U.S. Federal Cleanroom Standard 209E has generally been applied. Also, NASA Standard NHB5340.2 is used for microbes. Designs of clean rooms are usually based on these standards, however, operating conditions must be carefully taken into account.

Clean Room Ranking Table (ISO-14644-1, FS-209E)

CLEAN ROOM  
 
 

Clean Room Ranking Table

Cleanroom Manufacture of STERILE MEDICINAL PRODUCTS

Cleanroom AIR FLOW TYPE (Down Flow-Mau System)

Cleanroom class 1 to 100
(1) AIR ROOM (5) DRY COIL UNIT (8) PASS BOX (passing products or tools between two partitions)
(2) OUTER AIR DUCT (6) VERTICAL LAMINAR FLOW (9) THE SPACE FOR AIR RETURN
(3) FAN FILTER UNIT (7) AIRTIGHT DOOR (The door is keeping the cleanness and airtight of C/R. Generally, will install with air shower to keep the cleanness)    
(4) THE SPACE OF THE STEP-ON FLOOR        

CLEAN ROOM CEILING-GRID TYPE

back to top Arrow   back to top Arrow

CLEAN ROOM PARTITION

Cleanroom Color Steel Panel Construction

Cleanroom Wall / Ceiling
Cross-Sectional View
Cleanroom Partition / Ceiling
Cross-Sectional View
Cleanroom Partition / Ceiling
Cross-Sectional View

Cross-Sectional View of
Glass Window
Cleanroom Front Door View

Cleanroom Color Coated Steel

 

Cleanroom Medium Material of the Partition

back to top Arrow   back to top Arrow

CLEAN ROOM RAISED FLOOR

Cleanroom Cable TV Control Room

Down Flow Cleanroom System

Clean Room Floor

Cleanroom Construction

The Cleanroom Raised floor was composed of Aluminum Alloy and Ally Steel, which equips with high tension, tenacity and anti-corrosion. The prying value of Raised floor has to under 2mm, and the deformation has to lower than 0.01”(0.25mm). With proper color design and precise combination, the Raised floor would provide the highly quality of modern and cleanness environment.

Cleanroom Floor Specification

Honeycomb Floor Panel

Alloy Steel Blind Panel Composition

Floor Panel, Frame,
Base(Strong Type)

CLEAN ROOM RAISED FLOOR

Quakeproof Pureline

Base

Structural Drawing of Raised Floor
Floor, Panel, Frame, Base (Heavy Type)
Base
(Heavy & Standard)
Base (Strong)
back to top Arrow   back to top Arrow

CLEAN ROOM FLOOR ANTISTATIC & STATIC SEAMLESS

TECHNICAL DATA

All 6 colors are available in CONDUCTIVE TILE & STATIC-DISSIPATIVE TILE

back to top Arrow   back to top Arrow

Cleanroom Seamless Floor Construction

1. Make a groove at the middle between two tiles as the below illustration:(A)、(B)。
2. And then use heat-melt with the temperature around 70~80°C to decorate the groove with the same color plastic material.
3. After sealed, upon the temperature down to the normal atmospheric, and then flatting to keep the seamless floor for goood view.
 

back to top Arrow   back to top Arrow

Epoxy Floor For Clean Room

1. ILLUSTRATION FOR CLEANROOM FLOOR CONSTRUCTION

**THE FLOOR MUST BE AS SMOOTH AS POSSIBLE.

2. Cleanroom Floor CONSTRUCTION

Concrete Floor: (1) The new concrete must be flatting and drying at the regular condition, it must take at least 28 days, and the strength of concrete must be at least 3500lb.
(2) If there was old concrete under the new construction, the dirt must be cleaned very well, if any greasiness must be cleaned with special solvent, and then enough cleaning with natural lotion and dry enough as well.
(3) Cleaning the surface again with vacuum cleaner.
Base: With same scale of infilling and hardness mixing enough, it must be done within 5 hours.
Middle: After 3~5 hours, the base would turn dry, and next coating procedure must be done within 30-60 minutes.
Final Coating: Expoxy and hardener.
back to top Arrow   back to top Arrow

 

Clean Room Engineering & Construction | Clean Room Equipment | Sterile Equipments & Products |
Stainless Equipments | Clean Room Garments | Antistatic Shoes | Antistatic Chairs
Cleanroom Cleaning Products & Supplies:
Wiper | Gloves | Cleaning Products | Mask | Clean Paper & Notes | Apron/Arm Cover/Bag

Air System Enterprise Clean Room Expert Home | About Us | News | Clients | Contact Us

Air System Enterprise Taipei Head Office TEL: 886-2-2794-6262 FAX: 886-2-2791-4710
Copyright © 1985-2016 Air System Enterprise Co.,Ltd. All rights reserved